fence_rsa - Fence agent for IBM RSA

DESCRIPTION

fence_rsa is an I/O Fencing agent which can be used with the IBM RSA II management interface. It logs into an RSA II device via telnet and reboots the associated machine. Lengthy telnet connections to the RSA II device should be avoided while a GFS cluster is running because the connection will block any necessary fencing actions. fence_rsa accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent. fence_rsa can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts.

Vendor URL: http://www.ibm.com

PARAMETERS

        

-o, --action=<action>
Fencing Action (Default Value: reboot)         
-a, --ip=<ip>
IP Address or Hostname This parameter is always required.         
-l, --username=<name>
Login Name This parameter is always required.         
-p, --password=<password>
Login password or passphrase         
-S, --password-script=<script>
Script to retrieve password         
-c, --command-prompt=<prompt>
Force command prompt (Default Value: >)         
-x, --ssh
SSH connection         
-k, --identity-file=<filename>
Identity file for ssh         
-u, --ipport=<port>
TCP port to use for connection with device         
-v, --verbose
Verbose mode         
-D, --debug-file=<debugfile>
Write debug information to given file         
-V, --version
Display version information and exit         
-h, --help
Display help and exit         
--power-timeout
Test X seconds for status change after ON/OFF (Default Value: 20)         
--shell-timeout
Wait X seconds for cmd prompt after issuing command (Default Value: 3)         
--login-timeout
Wait X seconds for cmd prompt after login (Default Value: 10)         
--power-wait
Wait X seconds after issuing ON/OFF (Default Value: 0)         
--retry-on
Count of attempts to retry power on (Default Value: 1)         
--delay
Wait X seconds before fencing is started (Default Value: 0)

ACTIONS

        

on
Power on machine.         
off
Power off machine.         
reboot
Reboot machine.         
status
This returns the status of the plug/virtual machine.         
list
List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise.         
monitor
Check if fencing device is running. List available plugs/virtual machines or get status of machine (if it does not support more).         
metadata

 The operational behavior of this is not known.

STDIN PARAMETERS

        

action
Fencing Action (Default Value: reboot)         
ipaddr
IP Address or Hostname This parameter is always required.         
login
Login Name This parameter is always required.         
passwd
Login password or passphrase         
passwd_script
Script to retrieve password         
cmd_prompt
Force command prompt (Default Value: >)         
secure
SSH connection         
identity_file
Identity file for ssh         
ipport
TCP port to use for connection with device         
verbose
Verbose mode         
debug
Write debug information to given file         
version
Display version information and exit         
help
Display help and exit         
power_timeout
Test X seconds for status change after ON/OFF (Default Value: 20)         
shell_timeout
Wait X seconds for cmd prompt after issuing command (Default Value: 3)         
login_timeout
Wait X seconds for cmd prompt after login (Default Value: 10)         
power_wait
Wait X seconds after issuing ON/OFF (Default Value: 0)         
retry_on
Count of attempts to retry power on (Default Value: 1)         
delay